ARM: OMAP2+: DRA7: clockdomain: change l4per2_7xx_clkdm to SW_WKUP

commit b9e23f3219 upstream.

Legacy IPs like PWMSS, present under l4per2_7xx_clkdm, cannot support
smart-idle when its clock domain is in HW_AUTO on DRA7 SoCs. Hence,
program clock domain to SW_WKUP.

Signed-off-by: Vignesh R <vigneshr@ti.com>
Acked-by: Tero Kristo <t-kristo@ti.com>
Reviewed-by: Paul Walmsley <paul@pwsan.com>
Signed-off-by: Paul Walmsley <paul@pwsan.com>
Signed-off-by: Luis Henriques <luis.henriques@canonical.com>
This commit is contained in:
Vignesh R 2015-06-03 17:21:20 +05:30 • committed by Luis Henriques
commit 008bf0b6c9