clockevents: check broadcast tick device not the clock events device

Impact: jiffies increment too fast.

Hugh Dickins noted that with NOHZ=n and HIGHRES=n jiffies get
incremented too fast. The reason is a wrong check in the broadcast
enter/exit code, which keeps the local apic timer in periodic mode
when the switch happens.

Signed-off-by: Thomas Gleixner <tglx@linutronix.de>
This commit is contained in:
Thomas Gleixner 2008-10-04 10:51:07 +02:00
commit 07454bfff1