hwmon/w83627ehf: Preserve speed reading when changing fan min

The w83627ehf driver changes the fan clock divider automatically when
a new min fan speed is set. It is supposed to preserve the fan speed
reading while doing so, bug doesn't really. Fix it.

Signed-off-by: Jean Delvare <khali@linux-fr.org>
Signed-off-by: Mark M. Hoffman <mhoffman@lightlink.com>
This commit is contained in:
Jean Delvare 2007-06-17 16:09:12 +02:00 • committed by Mark M. Hoffman
commit 158ce07564