mmc: mediatek: add bus_clk control

when gate MSDC0_HCLK, access register will hang, even the MSDC driver
will never accessing register after HCLK was gated, but for safety, need
gate the bus_clk(which used to access register) too.

Signed-off-by: Chaotian Jing <chaotian.jing@mediatek.com>
Signed-off-by: Ulf Hansson <ulf.hansson@linaro.org>
This commit is contained in:
Chaotian Jing 2018-09-29 10:29:55 +08:00 • committed by Ulf Hansson
commit 258bac4a61