mlxsw: core: Extend hwmon interface with inter-connect temperature attributes

Add new attributes to hwmon object for exposing inter-connects temperature
input, highest, reset_history temperatures and label. Temperatures are read
from Management Temperature Register.
The number of inter-connect devices is read from Management General
Peripheral Information Register.

Signed-off-by: Vadim Pasternak <vadimp@mellanox.com>
Acked-by: Jiri Pirko <jiri@mellanox.com>
Signed-off-by: Ido Schimmel <idosch@mellanox.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
This commit is contained in:
Vadim Pasternak 2019-05-29 11:47:20 +03:00 • committed by David S. Miller
commit 2e265a8b6c