From 36be050f21dea7a3a76dff5a031da6274e8ee468 Mon Sep 17 00:00:00 2001 From: Shawn Lin Date: Mon, 22 Dec 2025 15:11:25 +0800 Subject: [PATCH] mmc: sdhci-of-dwcmshc: Prevent illegal clock reduction in HS200/HS400 mode commit 3009738a855cf938bbfc9078bec725031ae623a4 upstream. When operating in HS200 or HS400 timing modes, reducing the clock frequency below 52MHz will lead to link broken as the Rockchip DWC MSHC controller requires maintaining a minimum clock of 52MHz in these modes. Add a check to prevent illegal clock reduction through debugfs: root@debian:/# echo 50000000 > /sys/kernel/debug/mmc0/clock root@debian:/# [ 30.090146] mmc0: running CQE recovery mmc0: cqhci: Failed to halt mmc0: cqhci: spurious TCN for tag 0 WARNING: drivers/mmc/host/cqhci-core.c:797 at cqhci_irq+0x254/0x818, CPU#1: kworker/1:0H/24 Modules linked in: CPU: 1 UID: 0 PID: 24 Comm: kworker/1:0H Not tainted 6.19.0-rc1-00001-g09db0998649d-dirty #204 PREEMPT Hardware name: Rockchip RK3588 EVB1 V10 Board (DT) Workqueue: kblockd blk_mq_run_work_fn pstate: 604000c9 (nZCv daIF +PAN -UAO -TCO -DIT -SSBS BTYPE=--) pc : cqhci_irq+0x254/0x818 lr : cqhci_irq+0x254/0x818 ... Fixes: c6f361cba51c ("mmc: sdhci-of-dwcmshc: add support for rk3588") Cc: Sebastian Reichel Cc: Yifeng Zhao Signed-off-by: Shawn Lin Cc: stable@vger.kernel.org Signed-off-by: Ulf Hansson Signed-off-by: Greg Kroah-Hartman --- drivers/mmc/host/sdhci-of-dwcmshc.c | 7 +++++++ 1 file changed, 7 insertions(+) diff --git a/drivers/mmc/host/sdhci-of-dwcmshc.c b/drivers/mmc/host/sdhci-of-dwcmshc.c index 4e256673a098..5ae4e11b1e90 100644 --- a/drivers/mmc/host/sdhci-of-dwcmshc.c +++ b/drivers/mmc/host/sdhci-of-dwcmshc.c @@ -608,6 +608,13 @@ static void dwcmshc_rk3568_set_clock(struct sdhci_host *host, unsigned int clock sdhci_writel(host, extra, reg); if (clock <= 52000000) { + if (host->mmc->ios.timing == MMC_TIMING_MMC_HS200 || + host->mmc->ios.timing == MMC_TIMING_MMC_HS400) { + dev_err(mmc_dev(host->mmc), + "Can't reduce the clock below 52MHz in HS200/HS400 mode"); + return; + } + /* * Disable DLL and reset both of sample and drive clock. * The bypass bit and start bit need to be set if DLL is not locked.