rtc: pcf2127: adapt time/date registers write sequence for PCF2131

The sequence for updating the time/date registers is slightly
different between PCF2127/29 and PCF2131.

For PCF2127/29, during write operations, the time counting
circuits (memory locations 03h through 09h) are automatically blocked.

For PCF2131, time/date registers write access requires setting the
STOP bit and sending the clear prescaler instruction (CPR). STOP then
needs to be released once write operation is completed.

Signed-off-by: Hugo Villeneuve <hvilleneuve@dimonoff.com>
Link: https://lore.kernel.org/r/20230622145800.2442116-14-hugo@hugovil.com
Signed-off-by: Alexandre Belloni <alexandre.belloni@bootlin.com>
This commit is contained in:
Hugo Villeneuve 2023-06-22 10:57:56 -04:00 • committed by Alexandre Belloni
commit 3d715ebaf0