iio: mpl3115: use get_unaligned_be24() to retrieve pressure data
The pressure measurement result is arranged as 20-bit unsigned value residing in three 8-bit registers. Hence, it can be retrieved using get_unaligned_be24() and by applying 4-bit shift. Reviewed-by: Marcelo Schmitt <marcelo.schmitt1@gmail.com> Signed-off-by: Antoni Pokusinski <apokusinski01@gmail.com> Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
This commit is contained in:
parent
0de73abe5f
commit
47e4b1ca44
1 changed files with 10 additions and 3 deletions