scsi: storvsc: Support manual scans for all Hyper-V targets

The Fibre Channel transport topology created by storvsc exposes only one
dummy remote port per SCSI host. Its scsi_target_id is always zero.

As a result, the FC transport user-scan path looks up the remote port
using target ID 0. It cannot initiate a scan for Target 1 or higher. No
SCSI command is therefore sent to Hyper-V when userspace explicitly
requests a scan of one of these targets.

storvsc itself supports up to STORVSC_FC_MAX_TARGETS and already passes
scmnd->device->id to Hyper-V as vm_srb->target_id. Devices on Target 1
and higher work when initially discovered. They can also be rediscovered
by a full host scan, such as the scan triggered after an FC port bounce.

Provide a storvsc-specific user_scan callback that uses the exported
scsi_scan_target() interface. Iterate over the requested channel and
target ranges so that wildcard and explicitly addressed scans retain the
expected SCSI sysfs scan semantics.

This bypasses the single-rport lookup in fc_user_scan() and allows
userspace to explicitly scan any target supported by storvsc without
requiring one synthetic fc_rport for every Hyper-V target.

Signed-off-by: Laurence Oberman <loberman@redhat.com>
Link: https://patch.msgid.link/20260723163743.1274830-1-loberman@redhat.com
Signed-off-by: Martin K. Petersen (Oracle) <mkp@kernel.org>
This commit is contained in:
Laurence Oberman 2026-07-23 12:37:43 -04:00 • committed by Martin K. Petersen (Oracle)
commit 4c84c2e08a