drm/i915/icl: use ranges for voltage level lookup
Spec shows voltage level 0 as 307.2, 312, or lower and suggests to use range checks. Prepare for having other frequencies in these ranges by not comparing the exact frequency. v2: invert checks by comparing biggest cdclk first (suggested by Ville) Signed-off-by: Lucas De Marchi <lucas.demarchi@intel.com> Reviewed-by: Ville Syrjälä <ville.syrjala@linux.intel.com> Link: https://patchwork.freedesktop.org/patch/msgid/20190610214819.9703-1-lucas.demarchi@intel.com