staging: comedi: ni_mio_common: tidy up AO trigger selection

The AO subdevice (*cancel), ni_ao_reset(), always sets the private
data 'ao_trigger_select' to 0. So when a command is started the
'trigsel' value in ni_ao_cmd_set_trigger() will always start as 0.
Remove the unnecessary member from the private data.

The (*do_cmdtest) validates that the cmd->start_src will only be
TRIG_INT or TRIG_EXT. Refactor ni_ao_cmd_set_trigger() and remove
the BUG() which can never occur.

Signed-off-by: H Hartley Sweeten <hsweeten@visionengravers.com>
Reviewed-by: Ian Abbott <abbotti@mev.co.uk>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
This commit is contained in:
H Hartley Sweeten 2016-04-14 09:58:00 -07:00 • committed by Greg Kroah-Hartman
commit 55f9e7d9d3
2 changed files with 14 additions and 34 deletions