media: uvcvideo: Allow hw clock updates with buffers not full

With UVC 1.5 we get as little as one clock sample per frame. Which means
that it takes 32 frames to move from the software timestamp to the
hardware timestamp method.

This results in abrupt changes in the timestamping after 32 frames (~1
second), resulting in noticeable artifacts when used for encoding.

With this patch we modify the update algorithm to work with whatever
amount of values are available.

Tested-by: HungNien Chen <hn.chen@sunplusit.com>
Reviewed-by: Sergey Senozhatsky <senozhatsky@chromium.org>
Reviewed-by: Laurent Pinchart <laurent.pinchart@ideasonboard.com>
Signed-off-by: Ricardo Ribalda <ribalda@chromium.org>
Reviewed-by: Tomasz Figa <tfiga@chromium.org>
Link: https://lore.kernel.org/r/20240323-resend-hwtimestamp-v10-4-b08e590d97c7@chromium.org
Signed-off-by: Laurent Pinchart <laurent.pinchart@ideasonboard.com>
This commit is contained in:
Ricardo Ribalda 2024-03-23 10:48:05 +00:00 • committed by Laurent Pinchart
commit 6243c83be6