clocksource: davinci: only enable clockevents once tim34 is initialized

[ Upstream commit cea931c251 ]

The DM365 platform has a strange quirk (only present when using ancient
u-boot - mainline u-boot v2013.01 and later works fine) where if we
enable the second half of the timer in periodic mode before we do its
initialization - the time won't start flowing and we can't boot.

When using more recent u-boot, we can enable the timer, then reinitialize
it and all works fine.

To work around this issue only enable clockevents once tim34 is
initialized i.e. move clockevents_config_and_register() below tim34
initialization.

Signed-off-by: Bartosz Golaszewski <bgolaszewski@baylibre.com>
Signed-off-by: Sekhar Nori <nsekhar@ti.com>
Signed-off-by: Sasha Levin <sashal@kernel.org>
This commit is contained in:
Bartosz Golaszewski 2020-01-10 18:16:41 +01:00 • committed by Greg Kroah-Hartman
commit 6adf50d037