power: supply: leds: Share trig pointer for online and charging_full

Either 5 different LED triggers are registered for battery power-supply
devices or a single online LED trigger is used for non battery power-supply
devices.

These 5 / 1 LED trigger(s) are never used at the same time. So there is
no need for a separate LED trigger pointer for the online trigger. Rename
the first battery trigger from charging_full_trig to just trig and use this
for the online trigger too.

Signed-off-by: Hans de Goede <hdegoede@redhat.com>
Reviewed-by: Andy Shevchenko <andy@kernel.org>
Link: https://lore.kernel.org/r/20240531134702.166145-3-hdegoede@redhat.com
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
This commit is contained in:
Hans de Goede 2024-05-31 15:47:01 +02:00 • committed by Sebastian Reichel
commit 6c951a84da
2 changed files with 10 additions and 11 deletions