regulator: core: Fix logic to determinate if regulator can change voltage

Having a linear_min_sel setting means the first linear_min_sel selectors are
invalid. We need to subtract linear_min_sel when use n_voltages to determinate
if regulator can change voltage.

Signed-off-by: Axel Lin <axel.lin@ingics.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
This commit is contained in:
Axel Lin 2012-12-11 20:36:37 +08:00 • committed by Mark Brown
commit 8a23b4e03d