net: phy: dp8382x: keep WOL settings across suspends

Unlike other ethernet PHYs from TI, PHY dp8382x has WOL enabled
at reset. The driver explicitly disables WOL in config_init callback
which is called during init and during resume from suspend. Hence,
WOL is unconditionally disabled during resume, even if it was enabled
before the suspend. We make sure that WOL configuration is persistent
across suspends.

Signed-off-by: Catalin Popescu <catalin.popescu@leica-geosystems.com>
Reviewed-by: Simon Horman <horms@kernel.org>
Link: https://lore.kernel.org/r/20240408082602.3654090-1-catalin.popescu@leica-geosystems.com
Signed-off-by: Jakub Kicinski <kuba@kernel.org>
This commit is contained in:
Catalin Popescu 2024-04-08 10:26:02 +02:00 • committed by Jakub Kicinski
commit 9ef9ecfa9e