arm64: dts: hisilicon: Fix SP805 clocks

The SP805 DT binding requires two clocks to be specified, but
Hisilicon platform DTs currently only specify one clock.

In practice, Linux would pick a clock named "apb_pclk" for the bus
clock, and the Linux and U-Boot SP805 driver would use the first clock
to derive the actual watchdog counter frequency.

Since currently both are the very same clock, we can just double the
clock reference, and add the correct clock-names, to match the binding.

Signed-off-by: Andre Przywara <andre.przywara@arm.com>
Signed-off-by: Wei Xu <xuwei5@hisilicon.com>
This commit is contained in:
Andre Przywara 2020-09-07 13:18:29 +01:00 • committed by Wei Xu
commit a665b2c1d2
2 changed files with 9 additions and 6 deletions