mt76: fix beacon timer drift

The beacon timer drifts by 1 microsecond every TBTT. After 20 minutes
with a beacon interval of 100, the drift will be almost 12 ms, enough to
cause weird issues for devices in powersave mode.

Since the beacon timer is configured in units of 1/16 TU (64 us), we
need to adjust it once every 64 beacons and only for one beacon.

Signed-off-by: Felix Fietkau <nbd@nbd.name>
Signed-off-by: Kalle Valo <kvalo@codeaurora.org>
This commit is contained in:
Felix Fietkau 2018-06-21 11:17:53 +02:00 • committed by Kalle Valo
commit aea3827292
3 changed files with 41 additions and 2 deletions