power: supply: bq25890: Reduce reported CONSTANT_CHARGE_CURRENT_MAX for low temperatures

Take into account possible current reduction due to low-temperature when
reading POWER_SUPPLY_PROP_CONSTANT_CHARGE_CURRENT_MAX. As described in
the datasheet in cool (0-20° Celcius) conditions the current limit is
decreased to 20% or 50% of ICHG field value depended on JEITA_ISET field.

Also add NTC_FAULT field value to the debug message in
bq25890_get_chip_state().

Changed by Hans de Goede:
- Fix reading F_CHG_FAULT instead of F_NTC_FIELD for state->ntc_fault
- Only read JEITA_ISET field if necessary
- Tweak commit message a bit

Signed-off-by: Yauhen Kharuzhy <jekhor@gmail.com>
Reviewed-by: Andy Shevchenko <andriy.shevchenko@linux.intel.com>
Co-developed-by: Hans de Goede <hdegoede@redhat.com>
Signed-off-by: Hans de Goede <hdegoede@redhat.com>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
This commit is contained in:
Yauhen Kharuzhy 2022-02-01 14:06:49 +01:00 • committed by Sebastian Reichel
commit c562a43a46