staging: iio: adt7316: fix the dac read calculation

commit 45130fb030 upstream.

The calculation of the current dac value is using the wrong bits of the
dac lsb register. Create two macros to shift the lsb register value into
lsb position, depending on whether the dac is 10 or 12 bit. Initialize
data to 0 so, with an 8 bit dac, the msb register value can be bitwise
ORed with data.

Fixes: 35f6b6b86e ("staging: iio: new ADT7316/7/8 and ADT7516/7/9 driver")
Signed-off-by: Jeremy Fertic <jeremyfertic@gmail.com>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
Signed-off-by: Ben Hutchings <ben@decadent.org.uk>
This commit is contained in:
Jeremy Fertic 2018-12-22 21:57:42 -07:00 • committed by Ben Hutchings
commit cc7c2fefb9