OMAP3+: VC: use last nominal voltage setting to get current_vsel

Instead of reading current vsel value from the VP's voltage register,
just use current nominal voltage translated into vsel via the PMIC.

Doing this allows VC bypass scaling to work even without a VP configured.

Signed-off-by: Kevin Hilman <khilman@ti.com>
This commit is contained in:
Kevin Hilman 2011-07-18 15:31:00 -07:00
commit d7b0de2b46