HID: ft260: ft260_xfer_status routine cleanup

After clarifying with FTDI's support, it turned out that the error
condition (bit 1) in byte 1 of the i2c status HID report is a status
bit reflecting all error conditions. When bits 2, 3, or 4 are raised
to 1, bit 1 is set to 1 also. Since the ft260_xfer_status routine tests
the error condition bit and exits in the case of an error, the program
flow never reaches the conditional expressions for 2, 3, and 4 bits when
any of them indicates an error state. Though these expressions are never
evaluated to true, they are checked several times per IO, increasing the
ft260_xfer_status polling cycle duration.

The patch removes the conditional expressions for 2, 3, and 4 bits in
byte 1 of the i2c status HID report.

Signed-off-by: Michael Zaidman <michael.zaidman@gmail.com>
Tested-by: Guillaume Champagne <champagne.guillaume.c@gmail.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
This commit is contained in:
Michael Zaidman 2022-11-05 23:11:39 +02:00 • committed by Jiri Kosina
commit f45d50ede6