capacity_now should be assigned after comparing it to design_capacity.
Otherwise warning is printed even when capacity_now before assignment is
equal to design_capacity, making the check useless and "current charge level"
wrong (it should be higher than, not equal to, "maximum charge level", which
is full_charge_capacity):
"battery: reported current charge level (56410) is higher than reported
maximum charge level (56410)."
Fixes: 232de51437 (ACPI / battery: fix wrong value of capacity_now reported when fully charged)
Signed-off-by: Mariusz Ceier <mceier+kernel@gmail.com>
Cc: 3.16+ <stable@vger.kernel.org> # 3.16+
[rjw: Subject]
Signed-off-by: Rafael J. Wysocki <rafael.j.wysocki@intel.com>