linux/drivers/md/raid1.c
NeilBrown 4731b65de6 md/raid1: fix test for 'was read error from last working device'.
commit 34cab6f420 upstream.

When we get a read error from the last working device, we don't
try to repair it, and don't fail the device.  We simple report a
read error to the caller.

However the current test for 'is this the last working device' is
wrong.
When there is only one fully working device, it assumes that a
non-faulty device is that device.  However a spare which is rebuilding
would be non-faulty but so not the only working device.

So change the test from "!Faulty" to "In_sync".  If ->degraded says
there is only one fully working device and this device is in_sync,
this must be the one.

This bug has existed since we allowed read_balance to read from
a recovering spare in v3.0

Reported-and-tested-by: Alexander Lyakas <alex.bolshoy@gmail.com>
Fixes: 76073054c9 ("md/raid1: clean up read_balance.")
Signed-off-by: NeilBrown <neilb@suse.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
2015-08-10 12:21:55 -07:00

3197 lines
86 KiB