mirror of
https://git.kernel.org/pub/scm/linux/kernel/git/stable/linux.git/
synced 2026-09-26 18:16:26 +00:00
If the thermal subsystem returne -EPROBE_DEFER or any other error
when hwmon calls devm_thermal_zone_of_sensor_register(), this is
silently ignored.
I ran into this with an incorrectly defined thermal zone, making
it non-existing and thus this call failed with -EPROBE_DEFER
assuming it would appear later. The sensor was still added
which is incorrect: sensors must strictly be added after the
thermal zones, so deferred probe must be respected.
Fixes: d560168b5d ("hwmon: (core) New hwmon registration API")
Signed-off-by: Linus Walleij <linus.walleij@linaro.org>
Signed-off-by: Guenter Roeck <linux@roeck-us.net>